Toyota Land Cruiser

FJ60, FJ62 and FJ80 1980-1997 of release

Repair and operation of the car



Toyota Land Cruiser
+ 1. Maintenance instruction
+ 2. Maintenance
- 3. Engines
   + 3.1. Engines 2F and 3F-E
   + 3.2. Verkhneklapanny engine 1FZ-FE
   + 3.3. Dismantle and capital repairs of the engine
   - 3.4. Engine electric equipment
      3.4.1. Technical characteristics
      3.4.2. Battery
      3.4.3. Power cables
      + 3.4.4. System of ignition
      3.4.5. Ignition coil
      3.4.6. Ignition distributor
      3.4.7. Block of electronic ignition
      3.4.8. Induction sensor
      + 3.4.9. System of a charge of the battery
      3.4.10. Generator
      3.4.11. Generator details
      3.4.12. System of launch of the engine
      3.4.13. Starter electric motor
      3.4.14. Traction relay of a starter (car of 1980-87 of release)
+ 4. Cooling systems, heating
+ 5. Fuel and exhaust systems
+ 6. System of decrease in toxicity
+ 7. Transmission
+ 8. Brake system
+ 9. Suspension brackets and steering
+ 10. Body
+ 11. Electric equipment
+ 12. Electrical circuitries




eeac64fe


3.4.10. Generator

GENERAL INFORMATION

Details of installation of the generator

1. Tank of the hydraulic booster
2. Adjusting arm
3. Wire
4. Socket
5. Generator
6. Belt
7. Lock bolt
8. Axis

Removal and installation

PERFORMANCE ORDER
1. To lower the engine and to connect to a coupling case.
2. Disconnect sockets from the generator (are shown by shooters).
3. Weaken generator bolts (see rice. Details of installation of the generator).
4. Turn off and get adjusting and coupling bolts from an adjusting arm of the generator.
5. Remove the generator and an arm.
6. At acquisition of the new unit capture with yourself the old generator. Make sure that the new generator in accuracy corresponds to replaced. Pay attention to conclusions – their number, the sizes and a relative positioning have to be same, as on the replaced unit. At last, check marking. Marking has to be or is stamped on the case, or printed on a label and pasted on the case. Make sure that numbers on the new and replaced units coincide.
7. On many new generators there are no pulleys therefore it is necessary to rearrange a pulley from the replaced unit. At acquisition of the new generator consult concerning installation of a pulley.
8. Installation is carried out upside-down. Adjust a tension of a belt and check charge tension.